Daikin FDYAN140A-C2V 14.0kW Ducted 1 Phase Air Conditioning System

FDYAN140AV1 / RZA140C2V1 Daikin Standard Ducted System




$5,661.00 Incl GST
$5,146.36 Excl GST
In Stock


Calculate Shipping



Request Separate Shipping Quote
Best suited for large or bulky orders. After receiving your order, our team will contact you to arrange a custom shipping quote based on current freight market rates to your location. We work with multiple freight providers to find the best pricing and delivery option for your needs. Please note that final shipping costs will vary from the online shipping estimate.
Pick Up- $0.00 (ETA: 1 days)
Pick Up from our Brisbane Warehouse. Mon - Fri 8am - 4pm. Please wait for pickup confirmation call or email. Or contact us prior to picking up to ensure your unit is packed and ready to go.
Pick Up- $0.00 (ETA: 1 days)
Pick Up from our Sydney Warehouse. Mon - Fri 8am - 4pm. Please wait for pickup confirmation call or email. Or contact us prior to picking up to ensure your unit is packed and ready to go.

System FDYAN50A-C2V FDYAN60A-C2V FDYAN71A-C2V FDYAN85A-C2V FDYAN100A-C2V FDYAN125A-C2V FDYAN140A-C2V FDYAN160A-C2V
Indoor Unit FDYAN50AV1 FDYAN60AV1 FDYAN71AV1 FDYAN85AV1 FDYAN100AV1 FDYAN125AV1 FDYAN140AV1 FDYAN160AV1
Outdoor Unit RZA50C2V1 RZA60C2V1 RZA71C2V1 RZA85C2V1 RZA100C2V1 RZA125C2V1 RZA140C2V1 RZA160C2V1
Rated Cooling Capacity (kW) 5.0 6.0 7.1 8.5 10.0 12.5 14.0 15.5
Rated Heating Capacity (kW) 6.0 7.0 7.5 10.0 12.5 15.0 16.5 18.0
Power Supply 1 Phase, 220-240V, 50Hz
Power Input (Rated) Cool/Heat (kW) 1.35 / 1.62 1.78 / 1.95 2.20 / 1.93 2.53 / 2.80 3.10 / 3.35 3.94 / 4.00 4.30 / 4.50 4.95 / 4.90
EER / COP 3.70 / 3.70 3.37 / 3.59 3.23 / 3.89 3.36 / 3.57 3.23 / 3.73 3.17 / 3.75 3.26 / 3.67 3.13 / 3.67
TCSPF (Residential) Hot/Avg/Cold 4.42 / 3.72 / 3.65 4.35 / 3.75 / 3.75 4.42 / 3.86 / 3.92 4.28 / 3.84 / 3.89 4.28 / 3.87 / 3.96 4.25 / 3.90 / 4.01 4.19 / 3.86 / 3.96 4.05 / 3.76 / 3.86
HSPF (Residential) Hot/Avg/Cold 4.51 / 4.02 / 3.49 4.46 / 3.76 / 3.15 4.17 / 3.85 / 3.41 3.97 / 3.67 / 3.32 3.85 / 3.48 / 3.04 4.31 / 3.31 / 2.77 3.90 / 3.51 / 3.05 3.87 / 3.53 / 3.12
Airflow Rate (Nominal/Max) (L/s) 315 / 370 340 / 400 425 / 566 580 / 600 680 / 800 755 / 840 900 / 1000 950 / 1120
Indoor Sound Level @1.5m Cool/Heat (dBA) 33.3 / 45.0 34.1 / 44.0 37.3 / 46.0 42.0 / 45.0 43.5 / 44.0 44.2 / 46.0 46.6 / 47.9 47.9 / 50.7
Piping Length (m) 50
Indoor Fan Speeds H / M / L
Indoor Unit Dimensions (H x W x D) (mm) 300 x 1210 x 900 360 x 1520 x 935
Outdoor Unit Dimension (H x W x D) (mm) 595 x 845 x 300 990 x 940 x 320 1430 x 940 x 320
Indoor Unit Weight (kg) 37 40 45 55 56
Outdoor Unit Weight (kg) 45 69 78 93 99
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Pipe Sizes (Liquid/Gas) (mm) 6.35 / 12.7 9.52 / 15.88
Supply Air Opening (mm) HxW 185 x 852 245 x 1152
Return Air Opening (mm) 1 x 400 (Oval) 2 x 350 (Oval) 2 x 400 (Oval)
Outdoor Operating Range Cool/Heat (C) -5 to 46 / -15 to 16
EPA Sound Power Level (dBA) 68 70 71 72 73 75
Outdoor Sound Level @1m Cool/Heat (dBA) 48 / 51 51 / 54 52 / 54 53 / 56 54 / 56 56 / 58

(FDYAN140A-C2V)

System FDYAN50A-C2V FDYAN60A-C2V FDYAN71A-C2V FDYAN85A-C2V FDYAN100A-C2V FDYAN125A-C2V FDYAN140A-C2V FDYAN160A-C2V
Indoor Unit FDYAN50AV1 FDYAN60AV1 FDYAN71AV1 FDYAN85AV1 FDYAN100AV1 FDYAN125AV1 FDYAN140AV1 FDYAN160AV1
Outdoor Unit RZA50C2V1 RZA60C2V1 RZA71C2V1 RZA85C2V1 RZA100C2V1 RZA125C2V1 RZA140C2V1 RZA160C2V1
Rated Cooling Capacity (kW) 5.0 6.0 7.1 8.5 10.0 12.5 14.0 15.5
Rated Heating Capacity (kW) 6.0 7.0 7.5 10.0 12.5 15.0 16.5 18.0
Power Supply 1 Phase, 220-240V, 50Hz
Power Input (Rated) Cool/Heat (kW) 1.35 / 1.62 1.78 / 1.95 2.20 / 1.93 2.53 / 2.80 3.10 / 3.35 3.94 / 4.00 4.30 / 4.50 4.95 / 4.90
EER / COP 3.70 / 3.70 3.37 / 3.59 3.23 / 3.89 3.36 / 3.57 3.23 / 3.73 3.17 / 3.75 3.26 / 3.67 3.13 / 3.67
TCSPF (Residential) Hot/Avg/Cold 4.42 / 3.72 / 3.65 4.35 / 3.75 / 3.75 4.42 / 3.86 / 3.92 4.28 / 3.84 / 3.89 4.28 / 3.87 / 3.96 4.25 / 3.90 / 4.01 4.19 / 3.86 / 3.96 4.05 / 3.76 / 3.86
HSPF (Residential) Hot/Avg/Cold 4.51 / 4.02 / 3.49 4.46 / 3.76 / 3.15 4.17 / 3.85 / 3.41 3.97 / 3.67 / 3.32 3.85 / 3.48 / 3.04 4.31 / 3.31 / 2.77 3.90 / 3.51 / 3.05 3.87 / 3.53 / 3.12
Airflow Rate (Nominal/Max) (L/s) 315 / 370 340 / 400 425 / 566 580 / 600 680 / 800 755 / 840 900 / 1000 950 / 1120
Indoor Sound Level @1.5m Cool/Heat (dBA) 33.3 / 45.0 34.1 / 44.0 37.3 / 46.0 42.0 / 45.0 43.5 / 44.0 44.2 / 46.0 46.6 / 47.9 47.9 / 50.7
Piping Length (m) 50
Indoor Fan Speeds H / M / L
Indoor Unit Dimensions (H x W x D) (mm) 300 x 1210 x 900 360 x 1520 x 935
Outdoor Unit Dimension (H x W x D) (mm) 595 x 845 x 300 990 x 940 x 320 1430 x 940 x 320
Indoor Unit Weight (kg) 37 40 45 55 56
Outdoor Unit Weight (kg) 45 69 78 93 99
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Pipe Sizes (Liquid/Gas) (mm) 6.35 / 12.7 9.52 / 15.88
Supply Air Opening (mm) HxW 185 x 852 245 x 1152
Return Air Opening (mm) 1 x 400 (Oval) 2 x 350 (Oval) 2 x 400 (Oval)
Outdoor Operating Range Cool/Heat (C) -5 to 46 / -15 to 16
EPA Sound Power Level (dBA) 68 70 71 72 73 75
Outdoor Sound Level @1m Cool/Heat (dBA) 48 / 51 51 / 54 52 / 54 53 / 56 54 / 56 56 / 58
SKU FDYAN140A-C2V
Brand Daikin
Shipping Weight 148.0000kg
Shipping Width 0.433m
Shipping Height 1.430m
Shipping Length 1.520m
Shipping Cubic 0.941776000m3
Unit Of Measure ea

Daikin offers a 5-year warranty for all of their Air Conditioners and Controllers.

Be The First To Review This Product!

Help other Lawson Air Conditioning users shop smarter by writing reviews for products you have purchased.

Write a product review

Product Enquiry Form Complete this form to email us your enquiry.

FDYAN140A-C2V

 


Others Also Bought



More From This Category