Daikin Premium FCTA71A-VC2Y 7.1kW Streamer Cassette 3 Phase Air Conditioning System

FCTA71AVMA / RZAV71C2Y1 Daikin Streamer Cassette R32




$4,822.00 Incl GST
$4,383.64 Excl GST
In Stock


Calculate Shipping



Request Separate Shipping Quote
Best suited for large or bulky orders. After receiving your order, our team will contact you to arrange a custom shipping quote based on current freight market rates to your location. We work with multiple freight providers to find the best pricing and delivery option for your needs. Please note that final shipping costs will vary from the online shipping estimate.
Pick Up- $0.00 (ETA: 1 days)
Pick Up from our Brisbane Warehouse. Mon - Fri 8am - 4pm. Please wait for pickup confirmation call or email. Or contact us prior to picking up to ensure your unit is packed and ready to go.
Pick Up- $0.00 (ETA: 1 days)
Pick Up from our Sydney Warehouse. Mon - Fri 8am - 4pm. Please wait for pickup confirmation call or email. Or contact us prior to picking up to ensure your unit is packed and ready to go.

System Names FCTA71A-VC2Y FCTA85A-VC2Y FCTA100A-VF2Y FCTA125A-VF2Y FCTA140A-VF2Y
Indoor Unit FCTA71AVMA FCTA85AVMA FCTA100AVMA FCTA125AVMA FCTA140AVMA
Outdoor Unit RZAV71C2Y1 RZAV85C2Y1 RZAV100F2Y1 RZAV125F2Y1 RZAV140F2Y1
Cooling Capacity Rated/Min-Max (kW) 7.1 (3.2-8.0) 8.5 (4.0-10.0) 10.0 (3.5-13.5) 12.5 (3.5-15.0) 14.0 (3.5-16.5)
Heating Capacity Rated/Min-Max (kW) 8.0 (3.5-9.0) 10.0 (4.1-11.1) 12.0 (3.5-14.5) 15.0 (3.5-17.5) 16.5 (3.5-19.5)
Power Supply 3 Phase, 380-415V, 50Hz
Fascia Panel BYCQ125EAF
Wired Controller BRC1H62W
Power Consumption Cool/Heat (kW) 1.81 / 1.81 2.00 / 2.13 2.38 / 2.49 3.25 / 3.41 3.70 / 4.02
EER/COP (kW/kW) 3.92 / 4.42 4.25 / 4.69 4.21 / 4.81 3.85 / 4.40 3.78 / 4.10
AEER/ACOP 3.82 / 4.30 4.15 / 4.59 4.12 / 4.72 3.79 / 4.34 3.73 / 4.05
TCSPF Commercial Hot/Avg/Cold (Cooling) 5.59 / 5.54 / 5.84 5.76 / 5.70 / 6.00 7.55 / 8.11 / 9.37 7.02 / 7.39 / 8.45 6.75 / 7.25 / 8.24
TCSPF Residential Hot/Avg/Cold (Cooling) 5.14 / 4.47 / 4.50 5.35 / 4.70 / 4.72 6.49 / 5.68 / 5.82 6.09 / 5.44 / 5.66 5.91 / 5.35 / 5.58
HSPF Commercial Hot/Avg/Cold (Heating) 5.11 / 4.82 / 4.35 4.90 / 4.72 / 4.35 6.04 / 5.63 / 5.11 5.64 / 5.23 / 4.71 5.69 / 5.21 / 4.66
HSPF Residential Hot/Avg/Cold (Heating) 5.11 / 4.65 / 4.09 4.91 / 4.63 / 4.19 6.03 / 5.30 / 4.73 5.64 / 4.93 / 4.33 5.63 / 4.81 / 4.22
Indoor Unit Decoration Panel Colour Fresh White
Indoor Airflow Rate H/HM/M/ML/L (l/s) 383 / 350 / 308 / 267 / 225 575 / 517 / 458 / 400 / 333 608 / 558 / 500 / 442 / 383
Indoor Sound Pressure Level H/HM/M/ML/L (dBA) 37 / 36 / 34 / 31 / 27.5 45 / 42 / 39 / 36.5 / 34 46 / 43.5 / 41 / 38.5 / 36
Indoor Unit Dimensions mm (HxWxD) 256 x 840 x 840 298 x 840 x 840
Indoor Decoration Panel Dimensions mm (HxWxD) 50 x 950 x 950
Indoor Unit Weight (kg) 22 26
Indoor Decoration Panel Weight (kg) 5.5
Indoor Certified Operating Range Cool/Heat (C) 14 to 25 / 15 to 27
Outdoor Unit Colour Ivory White
Outdoor Unit Compressor Hermetically Sealed Swing Type
Outdoor Motor Output (kW) 2.40 3.30
Refrigerant Charge (R32) (kg) 2.60 (Charged for 30m) 2.90 (Charged for 30m) 3.20 (Charged for 40m) 3.70 (Charged for 40m)
Outdoor Sound Pressure Level Cool/Heat (dBA) 48 / 50 52 / 53 49 / 50 50 / 51 52 / 53
Outdoor Sound Pressure Level Night Quiet Mode (dBA) 44 48 45 46 48
Outdoor Sound Power Level (dBA) 67 71 68 - -
Outdoor Unit Dimensions mm (HxWxD) 990 x 940 x 320 870 x 1100 x 460
Outdoor Unit Weight (kg) 69 78 93 95
Outdoor Certified Operating Range Cool/Heat (C) -5 to 50 / -15 to 15.5
Pipe Sizes Liquid/Gas (mm) 9.5 / 15.9
Max Interunit Piping Length (m) 75 (Equivalent Length 90) 85 (Equivalent Length 100)
Max Installation Height Diff (m) 30
Heat Insulation Both Liquid and Gas Piping

(FCTA71A-VC2Y)

System Names FCTA71A-VC2Y FCTA85A-VC2Y FCTA100A-VF2Y FCTA125A-VF2Y FCTA140A-VF2Y
Indoor Unit FCTA71AVMA FCTA85AVMA FCTA100AVMA FCTA125AVMA FCTA140AVMA
Outdoor Unit RZAV71C2Y1 RZAV85C2Y1 RZAV100F2Y1 RZAV125F2Y1 RZAV140F2Y1
Cooling Capacity Rated/Min-Max (kW) 7.1 (3.2-8.0) 8.5 (4.0-10.0) 10.0 (3.5-13.5) 12.5 (3.5-15.0) 14.0 (3.5-16.5)
Heating Capacity Rated/Min-Max (kW) 8.0 (3.5-9.0) 10.0 (4.1-11.1) 12.0 (3.5-14.5) 15.0 (3.5-17.5) 16.5 (3.5-19.5)
Power Supply 3 Phase, 380-415V, 50Hz
Fascia Panel BYCQ125EAF
Wired Controller BRC1H62W
Power Consumption Cool/Heat (kW) 1.81 / 1.81 2.00 / 2.13 2.38 / 2.49 3.25 / 3.41 3.70 / 4.02
EER/COP (kW/kW) 3.92 / 4.42 4.25 / 4.69 4.21 / 4.81 3.85 / 4.40 3.78 / 4.10
AEER/ACOP 3.82 / 4.30 4.15 / 4.59 4.12 / 4.72 3.79 / 4.34 3.73 / 4.05
TCSPF Commercial Hot/Avg/Cold (Cooling) 5.59 / 5.54 / 5.84 5.76 / 5.70 / 6.00 7.55 / 8.11 / 9.37 7.02 / 7.39 / 8.45 6.75 / 7.25 / 8.24
TCSPF Residential Hot/Avg/Cold (Cooling) 5.14 / 4.47 / 4.50 5.35 / 4.70 / 4.72 6.49 / 5.68 / 5.82 6.09 / 5.44 / 5.66 5.91 / 5.35 / 5.58
HSPF Commercial Hot/Avg/Cold (Heating) 5.11 / 4.82 / 4.35 4.90 / 4.72 / 4.35 6.04 / 5.63 / 5.11 5.64 / 5.23 / 4.71 5.69 / 5.21 / 4.66
HSPF Residential Hot/Avg/Cold (Heating) 5.11 / 4.65 / 4.09 4.91 / 4.63 / 4.19 6.03 / 5.30 / 4.73 5.64 / 4.93 / 4.33 5.63 / 4.81 / 4.22
Indoor Unit Decoration Panel Colour Fresh White
Indoor Airflow Rate H/HM/M/ML/L (l/s) 383 / 350 / 308 / 267 / 225 575 / 517 / 458 / 400 / 333 608 / 558 / 500 / 442 / 383
Indoor Sound Pressure Level H/HM/M/ML/L (dBA) 37 / 36 / 34 / 31 / 27.5 45 / 42 / 39 / 36.5 / 34 46 / 43.5 / 41 / 38.5 / 36
Indoor Unit Dimensions mm (HxWxD) 256 x 840 x 840 298 x 840 x 840
Indoor Decoration Panel Dimensions mm (HxWxD) 50 x 950 x 950
Indoor Unit Weight (kg) 22 26
Indoor Decoration Panel Weight (kg) 5.5
Indoor Certified Operating Range Cool/Heat (C) 14 to 25 / 15 to 27
Outdoor Unit Colour Ivory White
Outdoor Unit Compressor Hermetically Sealed Swing Type
Outdoor Motor Output (kW) 2.40 3.30
Refrigerant Charge (R32) (kg) 2.60 (Charged for 30m) 2.90 (Charged for 30m) 3.20 (Charged for 40m) 3.70 (Charged for 40m)
Outdoor Sound Pressure Level Cool/Heat (dBA) 48 / 50 52 / 53 49 / 50 50 / 51 52 / 53
Outdoor Sound Pressure Level Night Quiet Mode (dBA) 44 48 45 46 48
Outdoor Sound Power Level (dBA) 67 71 68 - -
Outdoor Unit Dimensions mm (HxWxD) 990 x 940 x 320 870 x 1100 x 460
Outdoor Unit Weight (kg) 69 78 93 95
Outdoor Certified Operating Range Cool/Heat (C) -5 to 50 / -15 to 15.5
Pipe Sizes Liquid/Gas (mm) 9.5 / 15.9
Max Interunit Piping Length (m) 75 (Equivalent Length 90) 85 (Equivalent Length 100)
Max Installation Height Diff (m) 30
Heat Insulation Both Liquid and Gas Piping
SKU FCTA71A-VC2Y
Brand Daikin
Shipping Weight 96.5000kg
Shipping Width 0.514m
Shipping Height 0.990m
Shipping Length 0.940m
Shipping Cubic 0.523551000m3
Unit Of Measure ea

Daikin offers a 5-year warranty for all of their Air Conditioners and Controllers.

Be The First To Review This Product!

Help other Lawson Air Conditioning users shop smarter by writing reviews for products you have purchased.

Write a product review

Product Enquiry Form Complete this form to email us your enquiry.